Tested performance

The numbers, with their sources

>99.25%Capture at 0.1 µm125 PRO media. Nelson Laboratories flat-sheet media test, 0.1 µm NaCl aerosol.
98.5%Capture at 0.3 µmSeries 150 media, up to 98.5%. Manufacturer data.
112 daysIn service, no airflow restrictionField use in a high school, documented by an independent certified industrial hygienist.

Compared with MERV 13

Built for the particles MERV ratings leave out

ASHRAE Standard 52.2 rates MERV 13 filters to capture only about half of particles from 0.3 to 1.0 µm, and MERV ratings do not test below 0.3 µm at all.

Our 125 PRO media is tested at 0.1 µm, one third the smallest size in the MERV system.

125 PRO media at 0.1 µm
Over 99.25% (Nelson Laboratories)
Series 150 media at 0.3 µm
Up to 98.5% (manufacturer data)
MERV 13 at 0.3–1.0 µm
About 50% (ASHRAE 52.2 rating)

Figures come from different test methods and particle sizes, as labeled. They are not a single side-by-side test.

In the field

A school district study

An independent certified industrial hygienist compared our Series 150 filters with MERV 11 filters in comparable classrooms at a Phoenix-area high school over 109 days.

  • 37–83% fewer particles at every size measured (0.3–10 µm) on day 109
  • More than three months of service with adequate airflow and no mechanical breakdown
  • The district’s MERV 13 filters had loaded to capacity within days of installation

Preliminary evaluation with limited samples and no statistical analysis; rooms were similar but not identical. The consultant declared no financial interest.

Lower maintenance, less strain

Clogged filters choke airflow. In the study district, MERV 11 filters had to be changed every two weeks to a month, and the district reported frozen coils and other HVAC breakdowns. Our filters ran more than three months without either.

Media airflow resistance (Nelson Laboratories, 32 L/min): 125 PRO under 1.3 mm H2O.

Product line

Configured for your building

Media

125 PRO media

Our highest-efficiency media: over 99.25% at 0.1 µm in Nelson Laboratories testing.

2-Stage

Series 150 filters

Prefilter plus Series 150 media. The right fit for most classrooms, offices and clinical spaces.

3-Stage

Series 150 with carbon

Adds an activated carbon stage for exhaust and odor-control zones.

Series 90

Series 90 filters

Contact us for specifications and sizing.

The switchover

No retrofit. Four simple steps.

Reusable, double-gasketed holding frames install once in your existing housings. After that, new pads simply drop in.

1

Send your filter schedule

Building, unit location, size (W × H × D), quantity, 2- or 3-stage, plus an airflow reading.

2

We size to your housings

Pads are cut to fit the equipment you already have.

3

Frames install once

Reusable holding frames with a 10-year warranty replacement. Pads drop in at each change.

4

Written quote and delivery

Ships on payment or an approved purchase order. Made in the USA.

Where it is used

Commercial and institutional settings

Schools, offices and public spaces

Classrooms, administrative buildings, libraries and shared spaces.

Hospitals, clinics and medical offices

Waiting rooms, offices and general areas. Healthcare air handlers should be reviewed by your engineer.

Crew health and offshore

Vessels, platforms and crew quarters where people share air for long periods.

Commercial and institutional customers only; not sold for residential use. Our filters are air filtration products, not medical devices: they do not diagnose, treat, cure, mitigate or prevent disease, and they do not kill or inactivate microbes. They reduce airborne particles, including particles that can carry bacteria and viruses, in the air that passes through them. Filtration is one layer of protection alongside vaccination, ventilation and other public health measures.

Order for your facilities

Send your filter schedule for a written quote. Order air filters and air filtration systems: call 1-888-770-2001, press 3, then 2.